defaults {
udev_dir /dev
polling_interval 10
selector "round-robin 0"
path_grouping_policy failover
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
prio_callout "/bin/true"
path_checker tur
rr_min_io 100
rr_weight uniform
failback immediate
no_path_retry 12
user_friendly_names yes
}
blacklist {
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
devnode "^hd[a-z][[0-9]*]"
}
devices {
device {
vendor "HP|COMPAQ"
product "HSV1[01]1 \(C\)COMPAQ|HSV2[01]0|HSV300|HSV4[05]0"
path_grouping_policy group_by_prio
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_checker tur
path_selector "round-robin 0"
prio_callout "/sbin/mpath_prio_alua /dev/%n"
rr_weight uniform
failback immediate
hardware_handler "0"
no_path_retry 18
rr_min_io 100
}
device {
vendor "HP"
product "P2000 G3 FC|P2000G3 FC/iSCSI"
path_grouping_policy group_by_prio
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_checker tur
path_selector "round-robin 0"
prio_callout "/sbin/mpath_prio_alua /dev/%n"
rr_weight uniform
failback immediate
hardware_handler "0"
no_path_retry 18
rr_min_io 100
}
device {
vendor "HP"
product "OPEN-.*"
path_grouping_policy multibus
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_selector "round-robin 0"
rr_weight uniform
path_checker tur
hardware_handler "0"
failback immediate
no_path_retry 18
rr_min_io 1000
}
device {
vendor "HP"
product "MSA VOLUME*"
path_grouping_policy group_by_prio
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_checker tur
path_selector "round-robin 0"
prio_callout "/sbin/mpath_prio_alua /dev/%n"
rr_weight uniform
failback immediate
hardware_handler "0"
no_path_retry 18
rr_min_io 100
}
device {
vendor "HP"
product "MSA2012sa|MSA2312sa|MSA2324sa"
path_grouping_policy group_by_prio
getuid_callout "/sbin/hp_scsi_id -g -u -n -s /block/%n"
path_checker tur
path_selector "round-robin 0"
prio_callout "/sbin/mpath_prio_alua %d"
rr_weight uniform
failback immediate
hardware_handler "0"
no_path_retry 18
rr_min_io 100
}
device {
vendor "HP"
product "MSA2312fc|MSA2324fc|MSA2312i|MSA2324i"
path_grouping_policy group_by_prio
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_checker tur
path_selector "round-robin 0"
prio_callout "/sbin/mpath_prio_alua /dev/%n"
rr_weight uniform
failback immediate
hardware_handler "0"
no_path_retry 18
rr_min_io 100
}
device {
vendor "HP"
product "MSA2[02]12fc|MSA2012i"
path_grouping_policy multibus
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_selector "round-robin 0"
rr_weight uniform
path_checker tur
hardware_handler "0"
failback immediate
no_path_retry 18
rr_min_io 100
}
}